AllFiber → Field guides → OFS Furukawa fiber colors

OFS Furukawa fiber colors: tubes, ribbons, Lightera

OFS Furukawa fiber colors aren't a separate color code. None of the three OFS spec documents read for this guide prints a color table at all. They describe “color-coded buffer tubes” and leave the colors to the standard the cable was built to, so check the tubes against the TIA-598 color code chart. What's specific to OFS is everything around the colors: a part number field that says how many fibers sit in each tube, rollable ribbon tubes holding up to 288 fibers, ribbons identified by printed numbers and marks, and a company name that changed in 2025.

OFS cable now says Lightera

Start with the name on the reel, because it decides where the right documentation lives.

On March 6, 2025, Furukawa Electric announced it was combining three fiber cable units under one brand, Lightera: its Fiber Cable Division in Japan, OFS Fitel, LLC in the US, and Furukawa Electric LATAM S.A. in Brazil. The brand launched on April 1, 2025. The 2021 AccuTube+ sheet used for this guide carries “A Furukawa Company” under the OFS name, and the 2017 AccuTube+ brochure is now hosted on lightera.com.

Cable in the ground doesn't change its print when the company renames itself. A tech can open a closure and find a jacket that reads OFS, a work order that says Furukawa and a datasheet search that returns Lightera, all for the same family. Search all three names before deciding a sheet doesn't exist.

It also matters that “Furukawa” covers more than OFS. A Furukawa-labelled cable may have come from the Latin American or Japanese side of the group, and nothing in the OFS sheets speaks for those. On any Furukawa-labelled reel, look at tube 1 before trusting the US order. If it's red, the cable was built to a different standard, and International Fiber Color Codes: A Field Tech Guide covers the red-first schemes.

The S6 field is fibers per tube, and T doesn't mean one number

OFS part numbers on these sheets start with AT- and follow the same template: AT-S1 S2 SF S3 S4 S5 S6-NNN. The fields cover fiber selection, transmission performance, fiber type, sheath construction, tensile load, core type and, in S6, fibers per tube. The digits after the last dash are the fiber count.

Here's the trap. Both sheets use the letter T in S6, and it doesn't mean the same thing:

OFS cableFiber countWhat S6 = T means on the sheet
PowerGuide DT ADSS2 to 28812 fibers per tube
AccuTube+ Rollable Ribbon43272 fibers per tube
AccuTube+ Rollable Ribbon864144 fibers per tube
AccuTube+ Rollable Ribbon1728288 fibers per tube
AccuTube+ Rollable Ribbon3456144 fibers per tube

The rollable ribbon sheet even lists 576 as an available fiber count without a fibers-per-tube line for it. So read S6 together with the fiber count and the product family, never alone. If the sheet for that exact part number doesn't settle it, count what's in tube 1. And if a T in an OFS part number has ever left you expecting 12 fibers and finding a stack of ribbons, you were right to suspect it.

Compare that with the CommScope fiber color code guide, where a “12” in the part number didn't always mean 12 per tube, and with Prysmian fiber cable colors, where the ordering guide defines a fiber-grouping field outright. Three manufacturers, three different relationships between the part number and the tube.

AccuTube+ RR: the tube color tells you the least

On a 12-fiber-per-tube cable, the tube color and the fiber color together pin down one fiber. On AccuTube+ Rollable Ribbon, they don't come close.

Do the arithmetic from the sheet. At 432, 864 and 1728 fibers, the fibers-per-tube figures work out to six tubes every time (432 / 72, 864 / 144, 1728 / 288). The cable gets four times bigger and the tube count doesn't move. Every extra fiber goes into the same six tubes, so the blue tube on a 1728-fiber build holds 288 fibers in 12-fiber ribbons. That's 24 ribbons in one tube.

The 3456-fiber version goes the other way: 144 fibers per tube means 24 tubes, twice the 12 tube colors. Neither OFS document says how tubes 13 to 24 are told apart. Get that from the documentation for the part number before opening the sheath.

Which leaves the ribbons. The 2021 sheet calls it “ribbon print marking using blocks and bars,” and the 2017 brochure lists the ribbon identification method as “Numbers and Stripes/Blocks.” Neither document prints the table that maps a mark to a ribbon number, and neither lists the fiber colors inside a ribbon. Treat the printed number as the identifier and check the rest against OFS documentation for that cable.

One more difference from flat ribbon: OFS describes these as 250 µm fibers partially bonded to each other at predetermined points, so a ribbon can be rolled and routed like loose fiber. Rolled up in a tray, a ribbon's marking is easy to lose track of. Tag ribbons as they come out of the tube, not after they're all loose.

PowerGuide: color-coded tubes, 12 per tube on the DT sheet

PowerGuide is OFS's ADSS family. The PowerGuide DT sheet describes a gel-free cable from 2 to 288 fibers, with color-coded buffer tubes stranded around a dielectric central member using reverse oscillating lay (ROL) stranding for mid-span access. Its S6 field reads T = 12 fibers, so this is the build where the usual tube-then-fiber habit carries straight over.

Two cautions, though. The sheet says the cable is custom engineered per application, so a reel can differ from the catalog example. And the DT sheet is one PowerGuide variant. Other PowerGuide cables have their own sheets, and the fibers-per-tube field on yours is the one that counts.

Reading an OFS or Furukawa cable in the field

  1. Get the full part number from the work order, as-builts or reel tag, and note whether the jacket says OFS, Furukawa or Lightera.
  2. Find the sheet for that exact family. Search all three names.
  3. Read S6 against the fiber count. On a ribbon build, expect tens or hundreds of fibers per tube.
  4. Check tube 1. Blue points to the US order; red means find the standard before counting anything.
  5. On AccuTube+ RR, identify the ribbon by its printed marking before reading any fiber color.
  6. Splice only when the paperwork and the cable agree. If they don't, believe the cable and get the right documentation.

That's the honest limit of this guide: it rests on three OFS documents, and a datasheet describes a cable as it left the factory. It can't tell you what a crew did at the last closure.

Where the app fits

Fiber Optic Color Code Lookup ships 199 cable configurations, a mix of manufacturer-specific tube layouts from 6 manufacturers and generic standards layouts. The color codes hub lists the OFS / Furukawa lines it covers: PowerGuide, AccuTube+ Rollable Ribbon and Furukawa standard loose tube. Pick the build, then use forward lookup (fiber number to tube and color) or reverse lookup (colors to fiber number). The app carries 7 international color standards, switched in Settings, which matters the moment tube 1 turns out to be red.

Two cautions on ribbon builds for now. On AFL WTC and OFS AccuTube+ RR builds, the app shows a color for each ribbon that the cable doesn't carry, so go by the ribbon number. And until the next app update, its AccuTube+ RR 432 and 1728-fiber builds put 144 fibers in each tube instead of the 72 and 288 OFS lists, so on those two counts work from the sheet and the printed ribbon number.

All 98,898 pre-computed lookups live in a bundled database on the phone, so the app works the same in a manhole with zero signal as it does at the truck. The full app runs free for 24 hours with no account, then it's a single one-time $4.99 purchase. Nothing recurring.

Frequently asked questions

What color code does OFS fiber cable use?

None of the three OFS spec documents checked for this guide prints a color table. They describe color-coded buffer tubes without naming the colors. Check tube 1 on the cable itself against the US TIA-598 order: a red first tube means a different standard. For exact markings, use the OFS documentation for your part number.

How many fibers are in each tube of an OFS AccuTube+ Rollable Ribbon cable?

It depends on the fiber count. OFS's sheet lists 72 fibers per tube at 432 fibers, 144 at 864, 288 at 1728 and 144 at 3456, all in 12-fiber ribbons. The S6 field in the part number reads T for each of them, so read it together with the fiber count rather than on its own.

Is OFS the same company as Lightera?

Yes. Furukawa Electric announced on March 6, 2025 that OFS Fitel, its Japanese fiber cable division and Furukawa Electric LATAM would operate under one brand, Lightera, launched April 1, 2025. Older reels and datasheets still say OFS. When looking for a datasheet, search OFS, Furukawa and Lightera before concluding it does not exist.

Does Fiber Optic Color Code Lookup cover OFS cable without signal?

Yes. The color codes hub lists PowerGuide, AccuTube+ Rollable Ribbon and Furukawa standard loose tube among the app's builds, and all 98,898 pre-computed lookups are stored in a bundled database on the phone. Lookups work with zero signal in a manhole or vault. The full app is free for 24 hours, then a one-time $4.99 purchase.